Node.js v10.23.1 Documentation


Table of Contents

Net#

Stability: 2 - Stable

The net module provides an asynchronous network API for creating stream-based TCP or IPC servers (net.createServer()) and clients (net.createConnection()).

It can be accessed using:

const net = require('net');

IPC Support#

The net module supports IPC with named pipes on Windows, and UNIX domain sockets on other operating systems.

Identifying paths for IPC connections#

net.connect(), net.createConnection(), server.listen() and socket.connect() take a path parameter to identify IPC endpoints.

On UNIX, the local domain is also known as the UNIX domain. The path is a filesystem pathname. It gets truncated to sizeof(sockaddr_un.sun_path) - 1, which varies on different operating system between 91 and 107 bytes. The typical values are 107 on Linux and 103 on macOS. The path is subject to the same naming conventions and permissions checks as would be done on file creation. If the UNIX domain socket (that is visible as a file system path) is created and used in conjunction with one of Node.js' API abstractions such as net.createServer(), it will be unlinked as part of server.close(). On the other hand, if it is created and used outside of these abstractions, the user will need to manually remove it. The same applies when the path was created by a Node.js API but the program crashes abruptly. In short, a UNIX domain socket once successfully created will be visible in the filesystem, and will persist until unlinked.

On Windows, the local domain is implemented using a named pipe. The path must refer to an entry in \\?\pipe\ or \\.\pipe\. Any characters are permitted, but the latter may do some processing of pipe names, such as resolving .. sequences. Despite how it might look, the pipe namespace is flat. Pipes will not persist. They are removed when the last reference to them is closed. Unlike UNIX domain sockets, Windows will close and remove the pipe when the owning process exits.

JavaScript string escaping requires paths to be specified with extra backslash escaping such as:

net.createServer().listen(
  path.join('\\\\?\\pipe', process.cwd(), 'myctl'));

Class: net.Server[src]#

This class is used to create a TCP or IPC server.

new net.Server([options][, connectionlistener])#

net.Server is an EventEmitter with the following events:

Event: 'close'#

Emitted when the server closes. Note that if connections exist, this event is not emitted until all connections are ended.

Event: 'connection'#

Emitted when a new connection is made. socket is an instance of net.Socket.

Event: 'error'#

Emitted when an error occurs. Unlike net.Socket, the 'close' event will not be emitted directly following this event unless server.close() is manually called. See the example in discussion of server.listen().

Event: 'listening'#

Emitted when the server has been bound after calling server.listen().

server.address()[src]#

Returns the bound address, the address family name, and port of the server as reported by the operating system if listening on an IP socket (useful to find which port was assigned when getting an OS-assigned address): { port: 12346, family: 'IPv4', address: '127.0.0.1' }.

For a server listening on a pipe or UNIX domain socket, the name is returned as a string.

const server = net.createServer((socket) => {
  socket.end('goodbye\n');
}).on('error', (err) => {
  // handle errors here
  throw err;
});

// grab an arbitrary unused port.
server.listen(() => {
  console.log('opened server on', server.address());
});

Don't call server.address() until the 'listening' event has been emitted.

server.close([callback])[src]#

Stops the server from accepting new connections and keeps existing connections. This function is asynchronous, the server is finally closed when all connections are ended and the server emits a 'close' event. The optional callback will be called once the 'close' event occurs. Unlike that event, it will be called with an Error as its only argument if the server was not open when it was closed.

server.connections#

Stability: 0 - Deprecated: Use server.getConnections() instead.

The number of concurrent connections on the server.

This becomes null when sending a socket to a child with child_process.fork(). To poll forks and get current number of active connections, use asynchronous server.getConnections() instead.

server.getConnections(callback)[src]#

Asynchronously get the number of concurrent connections on the server. Works when sockets were sent to forks.

Callback should take two arguments err and count.

server.listen()[src]#

Start a server listening for connections. A net.Server can be a TCP or an IPC server depending on what it listens to.

Possible signatures:

This function is asynchronous. When the server starts listening, the 'listening' event will be emitted. The last parameter callback will be added as a listener for the 'listening' event.

All listen() methods can take a backlog parameter to specify the maximum length of the queue of pending connections. The actual length will be determined by the OS through sysctl settings such as tcp_max_syn_backlog and somaxconn on Linux. The default value of this parameter is 511 (not 512).

All net.Socket are set to SO_REUSEADDR (see socket(7) for details).

The server.listen() method can be called again if and only if there was an error during the first server.listen() call or server.close() has been called. Otherwise, an ERR_SERVER_ALREADY_LISTEN error will be thrown.

One of the most common errors raised when listening is EADDRINUSE. This happens when another server is already listening on the requested port/path/handle. One way to handle this would be to retry after a certain amount of time:

server.on('error', (e) => {
  if (e.code === 'EADDRINUSE') {
    console.log('Address in use, retrying...');
    setTimeout(() => {
      server.close();
      server.listen(PORT, HOST);
    }, 1000);
  }
});

server.listen(handle[, backlog][, callback])[src]#

Start a server listening for connections on a given handle that has already been bound to a port, a UNIX domain socket, or a Windows named pipe.

The handle object can be either a server, a socket (anything with an underlying _handle member), or an object with an fd member that is a valid file descriptor.

Listening on a file descriptor is not supported on Windows.

server.listen(options[, callback])[src]#

If port is specified, it behaves the same as server.listen([port[, host[, backlog]]][, callback]). Otherwise, if path is specified, it behaves the same as server.listen(path[, backlog][, callback]). If none of them is specified, an error will be thrown.

If exclusive is false (default), then cluster workers will use the same underlying handle, allowing connection handling duties to be shared. When exclusive is true, the handle is not shared, and attempted port sharing results in an error. An example which listens on an exclusive port is shown below.

server.listen({
  host: 'localhost',
  port: 80,
  exclusive: true
});

Starting an IPC server as root may cause the server path to be inaccessible for unprivileged users. Using readableAll and writableAll will make the server accessible for all users.

server.listen(path[, backlog][, callback])[src]#

Start an IPC server listening for connections on the given path.

server.listen([port[, host[, backlog]]][, callback])[src]#

Start a TCP server listening for connections on the given port and host.

If port is omitted or is 0, the operating system will assign an arbitrary unused port, which can be retrieved by using server.address().port after the 'listening' event has been emitted.

If host is omitted, the server will accept connections on the unspecified IPv6 address (::) when IPv6 is available, or the unspecified IPv4 address (0.0.0.0) otherwise.

In most operating systems, listening to the unspecified IPv6 address (::) may cause the net.Server to also listen on the unspecified IPv4 address (0.0.0.0).

server.listening#

  • <boolean> Indicates whether or not the server is listening for connections.

server.maxConnections#

Set this property to reject connections when the server's connection count gets high.

It is not recommended to use this option once a socket has been sent to a child with child_process.fork().

server.ref()[src]#

Opposite of unref(), calling ref() on a previously unrefed server will not let the program exit if it's the only server left (the default behavior). If the server is refed calling ref() again will have no effect.

server.unref()[src]#

Calling unref() on a server will allow the program to exit if this is the only active server in the event system. If the server is already unrefed calling unref() again will have no effect.

Class: net.Socket[src]#

This class is an abstraction of a TCP socket or a streaming IPC endpoint (uses named pipes on Windows, and UNIX domain sockets otherwise). A net.Socket is also a duplex stream, so it can be both readable and writable, and it is also an EventEmitter.

A net.Socket can be created by the user and used directly to interact with a server. For example, it is returned by net.createConnection(), so the user can use it to talk to the server.

It can also be created by Node.js and passed to the user when a connection is received. For example, it is passed to the listeners of a 'connection' event emitted on a net.Server, so the user can use it to interact with the client.

new net.Socket([options])#

  • options <Object> Available options are:

    • fd <number> If specified, wrap around an existing socket with the given file descriptor, otherwise a new socket will be created.
    • allowHalfOpen <boolean> Indicates whether half-opened TCP connections are allowed. See net.createServer() and the 'end' event for details. Default: false.
    • readable <boolean> Allow reads on the socket when an fd is passed, otherwise ignored. Default: false.
    • writable <boolean> Allow writes on the socket when an fd is passed, otherwise ignored. Default: false.
  • Returns: <net.Socket>

Creates a new socket object.

The newly created socket can be either a TCP socket or a streaming IPC endpoint, depending on what it connect() to.

Event: 'close'#

  • hadError <boolean> true if the socket had a transmission error.

Emitted once the socket is fully closed. The argument hadError is a boolean which says if the socket was closed due to a transmission error.

Event: 'connect'#

Emitted when a socket connection is successfully established. See net.createConnection().

Event: 'data'#

Emitted when data is received. The argument data will be a Buffer or String. Encoding of data is set by socket.setEncoding().

Note that the data will be lost if there is no listener when a Socket emits a 'data' event.

Event: 'drain'#

Emitted when the write buffer becomes empty. Can be used to throttle uploads.

See also: the return values of socket.write().

Event: 'end'#

Emitted when the other end of the socket sends a FIN packet, thus ending the readable side of the socket.

By default (allowHalfOpen is false) the socket will send a FIN packet back and destroy its file descriptor once it has written out its pending write queue. However, if allowHalfOpen is set to true, the socket will not automatically end() its writable side, allowing the user to write arbitrary amounts of data. The user must call end() explicitly to close the connection (i.e. sending a FIN packet back).

Event: 'error'#

Emitted when an error occurs. The 'close' event will be called directly following this event.

Event: 'lookup'#

Emitted after resolving the hostname but before connecting. Not applicable to UNIX sockets.

Event: 'ready'#

Emitted when a socket is ready to be used.

Triggered immediately after 'connect'.

Event: 'timeout'#

Emitted if the socket times out from inactivity. This is only to notify that the socket has been idle. The user must manually close the connection.

See also: socket.setTimeout().

socket.address()[src]#

Returns the bound address, the address family name and port of the socket as reported by the operating system: { port: 12346, family: 'IPv4', address: '127.0.0.1' }

socket.bufferSize#

net.Socket has the property that socket.write() always works. This is to help users get up and running quickly. The computer cannot always keep up with the amount of data that is written to a socket - the network connection simply might be too slow. Node.js will internally queue up the data written to a socket and send it out over the wire when it is possible. (Internally it is polling on the socket's file descriptor for being writable).

The consequence of this internal buffering is that memory may grow. This property shows the number of characters currently buffered to be written. (Number of characters is approximately equal to the number of bytes to be written, but the buffer may contain strings, and the strings are lazily encoded, so the exact number of bytes is not known.)

Users who experience large or growing bufferSize should attempt to "throttle" the data flows in their program with socket.pause() and socket.resume().

socket.bytesRead#

The amount of received bytes.

socket.bytesWritten#

The amount of bytes sent.

socket.connect()[src]#

Initiate a connection on a given socket.

Possible signatures:

This function is asynchronous. When the connection is established, the 'connect' event will be emitted. If there is a problem connecting, instead of a 'connect' event, an 'error' event will be emitted with the error passed to the 'error' listener. The last parameter connectListener, if supplied, will be added as a listener for the 'connect' event once.

socket.connect(options[, connectListener])[src]#

Initiate a connection on a given socket. Normally this method is not needed, the socket should be created and opened with net.createConnection(). Use this only when implementing a custom Socket.

For TCP connections, available options are:

  • port <number> Required. Port the socket should connect to.
  • host <string> Host the socket should connect to. Default: 'localhost'.
  • localAddress <string> Local address the socket should connect from.
  • localPort <number> Local port the socket should connect from.
  • family <number>: Version of IP stack, can be either 4 or 6. Default: 4.
  • hints <number> Optional dns.lookup() hints.
  • lookup <Function> Custom lookup function. Default: dns.lookup().

For IPC connections, available options are:

socket.connect(path[, connectListener])[src]#

Initiate an IPC connection on the given socket.

Alias to socket.connect(options[, connectListener]) called with { path: path } as options.

socket.connect(port[, host][, connectlistener])[src]#

Initiate a TCP connection on the given socket.

Alias to socket.connect(options[, connectListener]) called with {port: port, host: host} as options.

socket.connecting#

If true, socket.connect(options[, connectListener]) was called and has not yet finished. It will stay true until the socket becomes connected, then it is set to false and the 'connect' event is emitted. Note that the socket.connect(options[, connectListener]) callback is a listener for the 'connect' event.

socket.destroy([exception])#

Ensures that no more I/O activity happens on this socket. Only necessary in case of errors (parse error or so).

If exception is specified, an 'error' event will be emitted and any listeners for that event will receive exception as an argument.

socket.destroyed#

  • <boolean> Indicates if the connection is destroyed or not. Once a connection is destroyed no further data can be transferred using it.

socket.end([data][, encoding][, callback])[src]#

Half-closes the socket. i.e., it sends a FIN packet. It is possible the server will still send some data.

If data is specified, it is equivalent to calling socket.write(data, encoding) followed by socket.end().

socket.localAddress#

The string representation of the local IP address the remote client is connecting on. For example, in a server listening on '0.0.0.0', if a client connects on '192.168.1.1', the value of socket.localAddress would be '192.168.1.1'.

socket.localPort#

The numeric representation of the local port. For example, 80 or 21.

socket.pause()#

Pauses the reading of data. That is, 'data' events will not be emitted. Useful to throttle back an upload.

socket.pending#

This is true if the socket is not connected yet, either because .connect() has not yet been called or because it is still in the process of connecting (see socket.connecting).

socket.ref()[src]#

Opposite of unref(), calling ref() on a previously unrefed socket will not let the program exit if it's the only socket left (the default behavior). If the socket is refed calling ref again will have no effect.

socket.remoteAddress#

The string representation of the remote IP address. For example, '74.125.127.100' or '2001:4860:a005::68'. Value may be undefined if the socket is destroyed (for example, if the client disconnected).

socket.remoteFamily#

The string representation of the remote IP family. 'IPv4' or 'IPv6'.

socket.remotePort#

The numeric representation of the remote port. For example, 80 or 21.

socket.resume()#

Resumes reading after a call to socket.pause().

socket.setEncoding([encoding])#

Set the encoding for the socket as a Readable Stream. See readable.setEncoding() for more information.

socket.setKeepAlive([enable][, initialdelay])[src]#

Enable/disable keep-alive functionality, and optionally set the initial delay before the first keepalive probe is sent on an idle socket.

Set initialDelay (in milliseconds) to set the delay between the last data packet received and the first keepalive probe. Setting 0 for initialDelay will leave the value unchanged from the default (or previous) setting.

socket.setNoDelay([noDelay])[src]#

Disables the Nagle algorithm. By default TCP connections use the Nagle algorithm, they buffer data before sending it off. Setting true for noDelay will immediately fire off data each time socket.write() is called.

socket.setTimeout(timeout[, callback])[src]#

Sets the socket to timeout after timeout milliseconds of inactivity on the socket. By default net.Socket do not have a timeout.

When an idle timeout is triggered the socket will receive a 'timeout' event but the connection will not be severed. The user must manually call socket.end() or socket.destroy() to end the connection.

socket.setTimeout(3000);
socket.on('timeout', () => {
  console.log('socket timeout');
  socket.end();
});

If timeout is 0, then the existing idle timeout is disabled.

The optional callback parameter will be added as a one-time listener for the 'timeout' event.

socket.unref()[src]#

Calling unref() on a socket will allow the program to exit if this is the only active socket in the event system. If the socket is already unrefed calling unref() again will have no effect.

socket.write(data[, encoding][, callback])#

Sends data on the socket. The second parameter specifies the encoding in the case of a string. It defaults to UTF8 encoding.

Returns true if the entire data was flushed successfully to the kernel buffer. Returns false if all or part of the data was queued in user memory. 'drain' will be emitted when the buffer is again free.

The optional callback parameter will be executed when the data is finally written out - this may not be immediately.

See Writable stream write() method for more information.

net.connect()[src]#

Aliases to net.createConnection().

Possible signatures:

net.connect(options[, connectListener])[src]#

Alias to net.createConnection(options[, connectListener]).

net.connect(path[, connectListener])[src]#

Alias to net.createConnection(path[, connectListener]).

net.connect(port[, host][, connectlistener])[src]#

Alias to net.createConnection(port[, host][, connectListener]).

net.createConnection()#

A factory function, which creates a new net.Socket, immediately initiates connection with socket.connect(), then returns the net.Socket that starts the connection.

When the connection is established, a 'connect' event will be emitted on the returned socket. The last parameter connectListener, if supplied, will be added as a listener for the 'connect' event once.

Possible signatures:

The net.connect() function is an alias to this function.

net.createConnection(options[, connectListener])#

For available options, see new net.Socket([options]) and socket.connect(options[, connectListener]).

Additional options:

Following is an example of a client of the echo server described in the net.createServer() section:

const net = require('net');
const client = net.createConnection({ port: 8124 }, () => {
  // 'connect' listener
  console.log('connected to server!');
  client.write('world!\r\n');
});
client.on('data', (data) => {
  console.log(data.toString());
  client.end();
});
client.on('end', () => {
  console.log('disconnected from server');
});

To connect on the socket /tmp/echo.sock the second line would just be changed to:

const client = net.createConnection({ path: '/tmp/echo.sock' });

net.createConnection(path[, connectListener])#

Initiates an IPC connection.

This function creates a new net.Socket with all options set to default, immediately initiates connection with socket.connect(path[, connectListener]), then returns the net.Socket that starts the connection.

net.createConnection(port[, host][, connectlistener])#

Initiates a TCP connection.

This function creates a new net.Socket with all options set to default, immediately initiates connection with socket.connect(port[, host][, connectListener]), then returns the net.Socket that starts the connection.

net.createServer([options][, connectionlistener])[src]#

  • options <Object>

    • allowHalfOpen <boolean> Indicates whether half-opened TCP connections are allowed. Default: false.
    • pauseOnConnect <boolean> Indicates whether the socket should be paused on incoming connections. Default: false.
  • connectionListener <Function> Automatically set as a listener for the 'connection' event.
  • Returns: <net.Server>

Creates a new TCP or IPC server.

If allowHalfOpen is set to true, when the other end of the socket sends a FIN packet, the server will only send a FIN packet back when socket.end() is explicitly called, until then the connection is half-closed (non-readable but still writable). See 'end' event and RFC 1122 (section 4.2.2.13) for more information.

If pauseOnConnect is set to true, then the socket associated with each incoming connection will be paused, and no data will be read from its handle. This allows connections to be passed between processes without any data being read by the original process. To begin reading data from a paused socket, call socket.resume().

The server can be a TCP server or an IPC server, depending on what it listen() to.

Here is an example of an TCP echo server which listens for connections on port 8124:

const net = require('net');
const server = net.createServer((c) => {
  // 'connection' listener
  console.log('client connected');
  c.on('end', () => {
    console.log('client disconnected');
  });
  c.write('hello\r\n');
  c.pipe(c);
});
server.on('error', (err) => {
  throw err;
});
server.listen(8124, () => {
  console.log('server bound');
});

Test this by using telnet:

$ telnet localhost 8124

To listen on the socket /tmp/echo.sock the third line from the last would just be changed to:

server.listen('/tmp/echo.sock', () => {
  console.log('server bound');
});

Use nc to connect to a UNIX domain socket server:

$ nc -U /tmp/echo.sock

net.isIP(input)#

Tests if input is an IP address. Returns 0 for invalid strings, returns 4 for IP version 4 addresses, and returns 6 for IP version 6 addresses.

net.isIPv4(input)#

Returns true if input is a version 4 IP address, otherwise returns false.

net.isIPv6(input)#

Returns true if input is a version 6 IP address, otherwise returns false.